Our $600 Power Bill

About four years ago, we purchased a home in Napier to house our growing family.

Our home is a 1912 villa, renovated and extended from its original two bedrooms to a more spacious three bedrooms early 2000s.

All in all, the house is modern, well insulated and should have been pretty energy efficient. However, our first power bill was out-of-this-world expensive.

Let’s find out why it was so expensive – and how the problem was solved.

Power Bill Shock

After the first month being in our new home…. WOW.

Our power bill for May (not warm, not cold) was over $600 – so a seriously expensive power bill.

By comparison, we had just left a rental nearby which had a monthly power bill of less than $200 per month.  For the same size house, for the same size family.

I couldn’t understand why our power bill had suddenly tripled?! Something was seriously fishy.

 

So I got investigating.

In hot water

The way the house is wired for electricity assisted me in tracking down the source of the issue pretty fast.

The dual meter setup in the house includes an uncontrolled or ‘anytime’ meter and a controlled meter.

The uncontrolled meter supplies most of the house.

The controlled meter supplies only our hot water cylinder.  This allows the local distribution company to remotely switch off the hot water during peak load periods.

Our power bill showed that the controlled meter was using five times as much power as the rest of the house. OUCH.

How much hot water were we using exactly?!

Fault Finding

Our rental hot water heating was around $100 a month, so I struggled to understand how this had jumped to $500 per month just by moving house.

Initially I guessed that there was a hot water leak – which would result in energy literally flowing out of our the cylinder into the dirt.  But after a good amount of crawling around under a dusty house, I was both grumpy and couldn’t find the leak.

Having a chat to a smart electrical inspector at work the next day, he was certain it was either a leaking pipe or an incorrectly set temper valve.

A what valve?

Thermostats and temper valves

Water is heated in your cylinder to a temperature set by your thermostat. This turns power on / off to the cylinder to keep the water at a set temperature.

Modern thermostats typically have a minimum temperature of 60 degrees Celsius, to prevent the growth of Legionella bacteria.  This minimum is specified within the building code for modern cylinders like ours.

In a house with small kiddies (or oldies) however, some caution is required.  At 60 degrees Celsius, a child’s skin is burnt in just one second, compared to 40 seconds for water ten degrees lower (50 deg C).

Our house has the hot water cylinder right beside the kitchen, so not much heat is lost between the cylinder and tap.  Therefore the tap temperature needs to be lowered to reduce the risk of a burn.

Lowering of the tap temperature can be achieved by a tempering valve on the outgoing hot water pipe, which mixes the hot cylinder water (at 60 degrees) with fresh cold water when it exits the cylinder.

The setup at our place had a temper value and looked like the following diagram.  The hot water was directly mixed with cold tap water before heading off to the tap, shower etc.

A poorly set temper valve

Normally a house would have *just enough* cold water added to the hot water exiting the cylinder to achieve the desired tap temperature at the tap.

After some playing around, I figured out that our temper valve was set to maximum – mixing lots of cold water with the hot.

This must have made the water too cold at some point, so the previous homeowner compensated for it by setting the cylinder thermostat to maximum (somewhere around 90 degrees Celsius!).

This means that the cylinder was heating our hot water almost to boiling point and then mixing it with a heap of fresh cold water to make it a bearable temperature again.

As a test, I set the temper value to a minimum (only hot water was passing through) and reset the cylinder thermostat to the minimum.  Which was a smidgen above 60 degrees.

The next day I popped a thermometer under the kitchen tap.  The water was around 55 degrees and all seemed okay, so I left it like that to see what would happen.

The June power bill arrived and WHAM!  $220 including GST.

Around 2/3 less than the previous month.

Checking and resetting the thermostat and temper valve was saving almost $400 per month!

I had two thoughts –

  • the previous owners had really expensive power bills, and
  • I seriously owed my colleague a beer or three.

Setting Hot Water Temperature – The Right Way

1 – Set the hot water cylinder temperature to a minimum 60 degrees Celsius

2 – Measure the hot water temperature at kitchen and bathroom taps

3 – Adjust your temper value (if fitted) to achieve a suitable outlet temperature.